3 Buildings, elevators, etc. to be reported
Last Updated September 10, 2024
Buildings, building equipment, fire prevention equipment, elevators, and play facilities that require periodic reporting in Yokohama City
Buildings, building equipment, fire prevention equipment, elevators, and amusement facilities that require periodic reports in Yokohama City are stipulated by Cabinet Order (Article 16), as well as the "Yokohama City Building Standard Law Enforcement Detailed Regulations" (Article 6, Article 7, Article 7-2).
The following [Table 1] and [Table 2] describe the buildings, building equipment, and fire prevention equipment to be reported. In addition, we can confirm whether it is building targeted for report from "building, building equipment, fire prevention equipment (outside site) which needs periodic report based on Building Standard Act Article 12 in Yokohama-shi".
(1) Buildings
For each use category of A-1 to C-1 in [Table 1] below, those that fall under any of the scales in the right column "Eligible Items".
※[Table 1] Apartment houses and offices that do not have the use listed in the building are not subject to reports on "buildings", "building equipment", and "fire prevention equipment" in Yokohama City. However, elevators in buildings may be subject to reporting.
Applications | Targets (* 1, * 2) | ||
---|---|---|---|
A | A-1 | Theaters, movie theaters, viewing halls (excluding outdoor viewing halls) public hall, entertainment hall Meeting halls (including funeral halls, wedding halls, etc.) |
①S on the ground floor>100㎡(※5) |
A-2 | Hospitals, clinics, nursing care facilities for the elderly, etc. |
①S on the ground floor>100㎡(※5) |
|
A-3 |
Gymnasiums, museums, museums, libraries, bowling alleys, ski resorts, skating rinks, swimming pools, sports practice areas |
①S>100 on the 3rd floor or higher㎡ |
|
B | B-1 | Department stores, markets, stores that sell goods, exhibition halls, cabarets, cafes, nightclubs, bars, dance halls, amusement arcades, public baths, waiting areas, restaurants, restaurants, Katsuma voting ticket sales offices, off-site ticket sales offices, off-site Katsufune voting ticket sales offices |
①S on the ground floor>100㎡(※5) |
B-2 | Multipurpose Buildings (For use in two or more applications listed in this table) |
①S on the ground floor>100㎡(※5) |
|
B-3 | Private room video shops, etc. (*4) | ①S>100㎡(※5) |
|
C | C-1 | Child welfare facilities (child welfare facilities and nursing homes with accommodation facilities for residents), housing for the elderly with services, group homes for the elderly with dementia, group homes for the disabled |
①S on the ground floor>100㎡(※5) |
※1: S in the table refers to "total floor area of the part to be used for the purpose". In addition to each living room, corridors, warehouses, and other facilities are included in the “parts to be used for use”.
This includes parts related to the application, such as office rooms.
※2: Those whose target uses are only on the evacuation floor are not eligible (excluding private video shops, etc.).
※3: Excluding those attached to the school.
※4: "Private room video shops, etc." are only for those with private rooms divided by walls, ceilings, and doors.
For details, please refer to the addition of "private room video shops" (PDF: 517KB).
※5: The total floor area of the part to be used for the purposes listed in column 1 (i) of the Building Standards Act of the entire building is 200 m2 or less, and the entire building is
Unless the number of floors of the body is 2 or less.
(2) Building equipment and fire prevention equipment
Type | Targets | |
---|---|---|
Building equipment (mechanical ventilation equipment) | (1) Building equipment installed in buildings | |
Building equipment (mechanical smoke exhaust equipment) | (1) Building equipment installed in buildings | |
Building equipment (emergency lighting equipment) | (1) Building equipment installed in buildings | |
Fire protection equipment (Limited to those that can be closed or operated at any time (excluding fire dampers)) |
①(1) Fire prevention equipment installed in buildings ②Hospitals, floored clinics, child welfare facilities, etc. (limited to those who have accommodation facilities for residents) S of housing for the elderly with services, group homes for the elderly with dementia and group homes for the disabled>Fire protection equipment installed in a 200m2 building |
(3) Elevators and amusement facilities
Type | Targets |
---|---|
Elevators, tourist elevators, etc. | All (excluding those that are installed in dwelling units and have no unspecified number of uses and those specified by the Industrial Safety and Health Law) |
Amusement facilities |
Please refer to “4. Report Periods and Periods” for the reporting period and timing.
Inquiries to this page
Type | Contact information |
---|---|
About buildings, building equipment, fire prevention equipment | Building Safety Section, Building Guidance Division, Housing and Architecture Bureau Building Guidance Department Telephone: 045-671-4539 Fax: 045-681-2434 Email address: kc-anzen@city.yokohama.jp |
Elevators, etc. | Building Guidance Division, Housing and Architecture Bureau Building Guidance Department Telephone: 045-671-4538 Fax: 045-681-2434 Email address: kc-setsubi@city.yokohama.jp Telephone Reception hours |
You may need a separate PDF reader to open a PDF file.
If you do not have it, you can download it free of charge from Adobe.
To download Adobe Acrobat Reader DC
Page ID: 931-706-428