About publication such as earthquake-resistant diagnosis results of building where earthquake-resistant diagnosis was required
Last Updated March 27, 2024
Based on the "Law Concerning the Promotion of Seismic Retrofitting of Buildings (Act No. 123 of 1995)" For buildings that are required to conduct seismic diagnosis and report the results, For those who have not yet reported We publish the contents of order.
1.Target building
(1) Emergency safety confirmation Large-scale buildings
Buildings used by an unspecified number of people and those who need special consideration in evacuation, large-scale buildings that started construction before May 31, 1981
・"Scale requirements for large-scale buildings requiring earthquake-resistant diagnosis" (PDF: 68KB)
(2) Building with safety confirmation plan
A building facing a particularly important road (* 1) that should be secured in the event of an earthquake disaster, and above a certain height that was started before May 31, 1981 (* 2)
(※1) "Especially important roads that should be secured during an earthquake disaster" (PDF: 740KB)
(※2) "What is more than a certain height ..." (PDF: 22KB)
2.Details of the announcement
- Name, location, use, road name of building (limited to buildings with safety confirmation plan required)
- Name of the method of seismic diagnosis and the evaluation result of the safety of major parts of the building against earthquakes in terms of structural strength
- If there is a plan for seismic retrofitting, rebuilding or removal, the content and timing of implementation
3.Evaluation of earthquake-resistant diagnosis
The safety evaluation categories evaluated by the seismic diagnosis are I to III in the table below.
I | There is a high risk of collapse or collapse due to earthquake vibration and impact. | Insufficient earthquake resistance |
---|---|---|
II | There is a risk of collapse or collapse due to earthquake vibration and impact. | |
III | Low risk of collapse or collapse due to earthquake vibration and impact. | Seismic resistance is ensured |
The seismic diagnosis evaluates the risk of collapse or collapse due to a large-scale seismic motion with a seismic intensity of 6 to 7 or more.
For medium-scale seismic motions with a seismic intensity of about 5 or more, there is little risk of damage and there is little risk of collapse unless it is illegally constructed or degraded.
4.Publication of the results of seismic diagnosis
(If there is a change in the published content, such as when earthquake resistance is secured due to seismic retrofitting, etc., it will be updated as needed.)
(1) Emergency safety confirmation Large-scale buildings
- [Public facilities] List of earthquake-resistant diagnosis results (PDF: 485KB)(Updated on March 27, 2024)
- [Private facilities] List of seismic diagnosis results (PDF: 316KB)(Updated on July 19, 2023)
(2) Building with safety confirmation plan
- List of seismic diagnosis results (PDF: 519KB)(Updated on March 27, 2024)
- Status of earthquake resistance between intersections of seismic diagnosis required routes (PDF: 488KB)(Updated on March 27, 2024)
※About evaluation of safety for earthquake every building, according to confirmation method of earthquake resistance (PDF: 345KB), evaluation of attached table earthquake-resistant diagnosis and evaluation of safety against earthquake of main part in structural strength (PDF: 84KB) And the above "List of Seismic Diagnosis Results".
5.Order to report the results of the earthquake resistance diagnosis
An order has been issued to those who have not reported the results of the seismic diagnosis based on the provisions of Article 8, Paragraph 1 of the Act, and the contents will be announced based on the provisions of Paragraph 2 of the same Article.
6.Support for facilities that lack earthquake resistance
- Subsidiary system
We assist for earthquake-resistant repair design, earthquake-resistant repair work and removal work and support approach of earthquake resistance. For more information, please refer to the following website. - Seismic total support business (limited to buildings listed in the safety confirmation plan)
For buildings whose seismic diagnosis has been completed, a person with specialized knowledge and experience will visit the building owner so that the design and construction can be started systematically in the future. I will do it. For more information, please refer to the following website.
7.Press release
In order to open PDF files, you may need a separate PDF reader.
If you do not have it, you can download it free of charge from Adobe.
To download Adobe Acrobat Reader DC
For inquiries to this page
Building Disaster Prevention Section, Housing and Architecture Bureau Planning Department
Phone: 045-671-2928
Phone: 045-671-2928
Fax: 045-663-3255
Email address: kc-taishin@city.yokohama.jp
Page ID: 508-126-092