Menu

Close

Here's the text.

Information on Yokohama City Condominium Seismic Retrofit Improvement Promotion Project ※Application for 2024 has been closed.

Last Updated October 23, 2024

About application of 2024

Application for 2024 has been closed.
You can continue to consult with us about applications from the next fiscal year onwards.

Purpose of Business

In order to promote seismic retrofitting of condominiums and promote the creation of safe and earthquake-resistant towns, Residential Association Condominiums that carry out seismic retrofitting will provide seismic retrofitting design costs, seismic retrofitting costs, and construction supervision costs related to seismic retrofitting work. Aids

Target buildings

Target buildings

The target building shall satisfy all of the following:

A

Condominiums that were started with construction confirmation before the end of May 1981 and are subject to the Category Ownership Law and fall under any of the following. (changed from April 1, 2014)

  • Condominiums where the division owner lives more than half of the number of dwelling units
  • Condominiums with a floor area of 3 or more, excluding the basement, and a total area of 1,000 m2 or more

※ Not applicable if more than half of the total area is used for purposes other than apartment houses such as stores.

ICondominiums that have been determined to require seismic retrofitting as a result of this diagnosis (precision diagnosis) based on the city system.
※ When we carry out earthquake-resistant diagnosis without using this municipal system, or after having received this diagnosis by this municipal system, we carry out some earthquake-resistant repair work without using subsidy system of city If so, please consult the city.
C

At the time of seismic retrofitting design, evaluate the validity of the seismic retrofitting plan by a seismic assessment organization (* 1) and obtain any of the following 1 to 3 certifications or confirmations as necessary (* 2) (2017 Changed from April 1)

  1. Authorization of seismic retrofitting plans for buildings based on the provisions of Article 17, Paragraph 3 of the Seismic Retrofit Promotion Act
  2. Building confirmation based on the provisions of Article 6, Paragraph 1 of the Building Standards Act or Article 6-2, Paragraph 1
  3. Authorization of overall plans based on the provisions of Article 86-8, Paragraph 1 of the Building Standards Act

[Note]
※1 "Earthquake-resistant judgment organizations" are those who participated in the "National Network Committee for Existing Building Seismic Diagnosis and Renovation Promotion" (outside site) (external homepage) and registered based on the "Earthquake-resistant judgment committee setting registration guidelines" Refers to an earthquake-resistant judgment organization or an organization that the mayor recognizes as equivalent.
※2 In the case of seismic retrofitting design using the partial renovation system, make sure that the above certifications from 1 to 3 are not required.
[Note: Condominiums that require seismic diagnosis]
1.Emergency safety confirmation Large-scale buildings
  Condominiums with facilities used by a large number of people as listed in Article 3, Paragraph 1 of the Supplementary Provisions of the Seismic Retrofit Promotion Act, and large-scale condominiums that meet all of the following requirements.

2.Buildings listed in the safety confirmation plan required
  Condominiums along the road designated by the city as roads that should be secured in the event of an earthquake disaster, listed in Article 7, Paragraph 1, Item 3 of the Seismic Retrofit Promotion Act, and refer to those of a certain height or more, all of the following:
  Condominiums that meet the requirements of the above.

※ Before submitting a subsidy grant application, etc., submit the “Confirmation Form for Buildings subject to Seismic Diagnosis under the Seismic Retrofit Promotion Act” (Excel: 24KB) and the “Preliminary Consultation Form” (word: 35KB) to the City of Yokohama, Housing and Architecture Bureau Planning Department Building Disaster Prevention Section to confirm that they fall under 1 or 2 above.

DHave not received an order for seismic retrofitting based on the Building Standards Law.

※Requirements about the scale of buildings have disappeared from 2013.
※Please collect quotes from three or more parties.
Please refer to the following page for the operation after April 1, 2021.


※The application for 2024 was closed on October 21, 2024.
※Depending on the budget situation, we may not be able to accept applications, so be sure to consult with the Building Disaster Prevention Section in advance before collecting quotes and resolutions at the General Assembly of Residential Association. (However, prior consultation does not guarantee the grant of subsidies. Reception will be conducted in the order in which the required documents set is ready, not in the order of prior consultation. )

Supplementary contents

Of the expenses required for seismic retrofitting work, we will provide assistance to the following amounts for seismic retrofitting design costs, seismic retrofitting construction costs, and construction supervision costs pertaining to seismic retrofitting work.
In addition, construction supervision pertaining to seismic retrofitting design and seismic retrofitting work shall be carried out by architects who fall under Article 5, Paragraph 1, Item 1 or Item 2 of the Enforcement Regulations of the Seismic Retrofit Promotion Act. (changed from April 1, 2017)
In addition, please refer to Building Disaster Prevention Section as apartment with part owned by public organizations such as local governments becomes subsidy amount according to expense burden ratio of public organization.

Supplementary contents
ASeismic retrofit design
The lower of the following amounts
・2/3 of the seismic retrofit design cost (estimated by the operator * 1)
・2/3 of the total floor area of condominiums multiplied by 1,000 yen/m2 and added 5.4 million yen.
※1 “Seismic retrofit design costs” can include the costs related to “Evaluation of the validity of the seismic retrofit plan by the seismic assessment organization”.
IConstruction supervision related to seismic retrofitting work
2/3 of construction supervision costs (estimated by businesses) related to seismic retrofitting work
C

(1) Total renovation work (a renovation work that ensures that the entire condominium is safe against earthquakes in a single construction)
1/3 of the seismic retrofitting work cost (estimated by the company) or the following limit, whichever is lower (* 3) (* 4)

Limits
Total area
(Calculated for each building under the Building Standards Law)
Limits
Less than 5,000 m220 million yen
5,000m2 or more and less than 10,000m235 million yen
10,000 m2 or more50 million yen

(2) Step-by-step renovation work (renovation work that divides the work into two parts to ensure that the entire condominium is safe against earthquakes)
1/3 of the seismic retrofitting work cost (estimated by the company) or the following limit, whichever is lower (* 2) (* 3)

Limits
Total area
(Handling under the Building Standards Law)
Calculated for each building)
1st Seismic Retrofitting
Amount of limit
2nd Seismic Retrofitting
Amount of limit
Less than 5,000 m210 million yen20 million yenFrom the forehead on the left
In the 1st Seismic Retrofit
The amount of subsidy issued
Amount deducted
5,000m2 or more and less than 10,000m217.5 million yen35 million yen
10,000 m2 or more25 million yen50 million yen

(3) Partial renovation work (work to rehabilitate weaknesses such as the piloti floor in advance)
1/3 of the seismic retrofitting work cost (estimated by the company) or the following limit, whichever is lower (* 3) (* 4)

Limits
Total area
(In accordance with the Building Standards Law)
In the handling of
Calculated for each building)

1st Seismic
Renovation work
Limits

2nd and subsequent renovation work
Amount of limit
Maximum amount of final work (construction that ensures the entire condominium is safe)
Less than 5,000 m210 million yen16 million yen

From the forehead on the left
Amount obtained by subtracting the amount of subsidy issued in the seismic retrofitting work so far

20 million yenFrom the forehead on the left
Amount obtained by subtracting the amount of subsidy issued in the seismic retrofitting work so far
5,000 m2 or more
Less than 10,000 m2
17.5 million yen28 million yen35 million yen
10,000 m2 or more25 million yen40 million yen50 million yen

[Note]
※2 However, "Condominium where the building site of the apartment is in contact with" Roads to be secured in the event of an earthquake disaster "(PDF: 430KB) and falls under" buildings over a certain height "(PDF: 22KB) " ,
Either 2/3 of the seismic retrofitting work cost or the limit in the table above, whichever is lower
It's a coincidence. (changed from November 25, 2013)
※3 In the case of "Emergency Safety Confirmation Large-scale Buildings Required" or "Building Required for Safety Confirmation Plan" for which seismic diagnosis of condominiums is mandatory, additional assistance rates may be added separately.

[Application Documents]

Please check the following checklist for documents at the time of application for seismic retrofitting design or seismic retrofitting work.

〇 Documents to be submitted checklist (seismic retrofit design) (PDF: 82KB)

〇 Documents to be submitted checklist (construction supervision pertaining to seismic retrofitting work and seismic retrofitting work) (PDF: 84KB)

Brochure

System outlines, assistance guidelines, etc.

Others

As mentioned above, the contents are as of April 1, 2023, and the contents of the subsidy may be changed due to national system revisions.

You may need a separate PDF reader to open a PDF file.
If you do not have it, you can download it free of charge from Adobe.
Get Adobe Acrobat Reader DCTo download Adobe Acrobat Reader DC

Inquiries to this page

Building Disaster Prevention Section, Housing and Architecture Bureau Planning Department