Menu

Close

Here's the text.

C-094: Shin-Sugita Station South Area

City planning decision: July 5, 2013

Last Updated December 9, 2022

・Plan
Name Shin-Sugita Station South District Planning
Position Shinsugita-cho, Isogo-ku
Area Approx. 0.8ha
Goals of District Planning This area is located around Sugita / Shinsugita Station, which is the base of the area positioned in the Isogo Ward Plan of Urban Planning Master Plan, and is served by the JR Negishi Line and Kanazawa Seaside Line, and is an access base to industrial areas in the coastal area. Station square of Sugita Station (refers to the traffic plaza on the Sugita Line of the city planning road 3.5.18 Sugita Line. The same shall apply hereinafter.)
In the vicinity of this area, commercial facilities, nursery schools, inhabitant of a ward cultural center, etc. have been developed through urban redevelopment projects, and community care plazas, sports centers, nursing centers, etc. are also located, and the accumulation of local base functions Is progressing.
This district plan takes advantage of the location characteristics of the station square, and plays a part in the local base together with the surrounding urban area. The goal is to create a safe, comfortable and lively urban area by securing spaces.
Ward
Regions
For
Ordering
Equipment

Open
Departure
Oh
Frog
Holding
All
To
Seki

L
How
Needle
Land Use Policy In order to form a local base that supports civil life, land use as a complex urban area with commercial and business functions and urban housing. In particular, taking into account the location characteristics of the Area, we plan to establish housing for the elderly and child-raising households, childcare facilities, and health check-up and medical facilities that contribute to the health management of workers in the coastal area.
In order to create a lively area in front of the station, convenience facilities and plazas will be placed continuously in the station square.
In order to form a safe and comfortable urban area, a plaza, pedestrian spaces, and green spaces will be maintained.
Policy for the development of district facilities A sidewalk-like open space will be placed along the station square and Shinsugita Route 78 to form a safe and comfortable pedestrian space. In addition, open space 1 and Plaza 2 will be places for breaks and talks continuously with these sidewalk-like open spaces. In particular, Square 2 will be developed as a plaza with a disaster prevention function.
We arrange green tract of land along city road Shinsugita Route 117 and city planning road 3.1.5 Route 357 and form moist pedestrian space.
On the roof of the station square side of the building, there will be a place where everyone can easily access the elevator and provide a place for rest and talk. In the event of an emergency such as tsunamievacuation sites. In addition, one pedestrian passageways that can access square 3 from the ground will be developed in the east and west.
To improve the convenience of Shinsugita Station, a parking lot for motorcycles will be placed along Shinsugita No. 117 on the city road.
Policy of maintenance such as buildings In order to guide the maintenance of buildings based on the following policies, restrictions on the use of buildings, the maximum floor area ratio of buildings, the minimum floor area ratio of buildings, the maximum building coverage ratio of buildings, buildings We establish minimum of site area, limit of position of wall surface, maximum height of building height, limit of form design such as buildings and minimum of tree planting rate of building.
Aim for advanced use appropriate for one base, reduce the feeling of oppression around the district, and form a cityscape in harmony with the surrounding urban area.
2 Through the guidance of functions such as commerce and business, health check-up / medical treatment, and childcare, we will create a lively space and enhance the base functions that support citizens' lives.
3 Secure an open space on the outer perimeter of the building to form a spacious urban environment.
Greening Policy In order to create a moist and attractive cityscape and suppress the heat island phenomenon, we will maintain green spaces in district facilities and establish a minimum greening rate of buildings in order to actively promote greening on the premises.
・Plan (continued)
c-094 District Development Plan
Placement and scale of district facilities Square 1 Area about 60㎡ Some non-blue sky
Square 2 Area approx. 300㎡  
Square 3 Area approx. 900㎡  
Green space 1 Area about 180㎡  
Green Space 2 Area approx. 400㎡  
Side-shaped open space 1 Width 2.0m Extended about 40m  
Side-shaped open space 2 4.0m wide Extension about 110m  
Pedestrian Passage 1 Width 2.0m Extended about 20m or more Some non-blue sky
The passage from the ground to the square 3.
Pedestrian Passage 2 Width 2.0m Extended about 20m or more Some non-blue sky
The passage from the ground to the square 3.
Parking lot Area approx. 130㎡  
Construction
Construction
Goods
Etc.
To
Seki

L
Things
Item 2
Restrictions on the use of buildings The buildings listed below shall not be constructed.
1 The first floor is used for housing (excluding those where only the corridors, halls, stairs, elevators, and other similar items used for housing on the first floor are only corridors, halls, stairs, elevators and the like).
2 Driving Schools
3 Livestock barns of the scale prescribed in Article 130-7 of the Building Standards Law Enforcement Ordinance (1950 Cabinet Order No. 338)
4 Mahjong shop, pachinko shop, shooting area, Katsuma voting ticket sales office, off-site ticket office, and the like
5 Karaoke boxes and other similar items
6 Warehouses engaged in warehousing business
7 Factories (excluding those attached to stores, restaurants and other buildings provided for similar purposes)
8 Items to be used for storing or processing dangerous goods (excluding storage facilities for own use and the like)
Maximum floor area ratio of buildings The maximum floor area ratio of the building to be used for the house (including facilities such as elevators attached to the part) of the building including the part to be used for the house or the part to be used for housing is 10 minutes 23.
Minimum floor area ratio of buildings The minimum floor area ratio of the buildings listed below (hereinafter referred to as "schools, etc." in this section) or parts to be used for schools, etc., to be used for schools, etc. is 7/10 And Provided, however, that this shall not apply to public toilets, police officers, and other similar buildings necessary for the public interest.
1 School
2 Libraries, museums and other similar
3 Meeting venue
4 Exhibition Hall
5 Nursery schools
6 clinics
7 Stores that sell goods, restaurants, or stores that operate service businesses
8 Atelier or workshop for making art or crafts
9 Study cram schools, flower arrangement classes, go classes, and the like
10 bowling alleys, skating rinks, swimming area and other similar sports facilities
11 Hotels or inns
12 Offices
13 theaters, movie theaters, theaters or viewing halls
14 Public Baths
15 Nursing homes, welfare homes for the physically handicapped, and the like (excluding those that have rooms used by those who move in, enter, or hospitalized)
16 Welfare centers for the elderly, elementary school student welfare facilities, and the like (excluding those with rooms used by those who move in, enter, or hospitalized)
17 Those attached to the buildings of the preceding items (excluding car garages and other exclusively for stopping or parking of cars or bicycles)
The maximum building coverage ratio Five-tenths
Minimum floor area of the building 3,000 ㎡
Provided, however, that this shall not apply to public toilets, police offices, and other facilities that are used as sites for public interest.
Restrictions on wall position The outer wall of the building or the surface of the pillar in place of this shall not be built beyond the limit of the position of the wall shown in the plan.
The maximum height of the building The height of the building must not exceed 20m in the area a shown in the plan drawing and 45m in the area of Area A shown in the plan drawing.
Restrictions on form design of buildings, etc.

Form designs such as 1 buildings shall conform to the following matters in order to consider landscape harmony to the surroundings.
(1) In order to reduce the feeling of pressure and longness caused by the wall of the building, the part of the building exceeding 20m must have a horizontal length of 70m or less, projected on the vertical surface of the part. In addition, it shall be a form design that divides the wall by the design and color of pillars.
(2) The first floor facing the station square of the building shall be designed so that activities inside the building and liveliness of the building can be seen, such as by providing openings.
(3) Building equipment (excluding solar power generation facilities and solar heat utilization equipment) installed on the roof of the building shall be surrounded by shielding materials in harmony with the building, so that they do not have a messy appearance.
(4) The parking lot or bicycle parking lots should not have a messy appearance, such as by planting.
(5) The color of the building should be based on a brightness of 6 or more and a saturation of 3 or less in yellow-red (YR) or yellow (Y) system of Munsell color (N) and 6 or more. However, solar power generation facilities, solar heat utilization equipment, or glass surface parts are excluded.
(6) The color of the building part that exceeds 20m in height of the building shall be based on a color that is higher brighter than the base color of the building part 20m or less.
2 Outdoor advertising materials shall conform to the following items in order to consider landscape harmony to the surroundings. Provided, however, that this shall not apply to information signs and other items that are deemed to need to be installed for public purposes.
(1) Outdoor advertising materials can be installed only as long as those related to business or business in the district or those that display names such as houses.
(2) Do not use video equipment.
(3) The saturation of the part that occupies two-thirds of the display area of outdoor advertising materials shall be 9 or less.
(4) When we install outdoor advertising matter in buildings, do not install in part more than 20m of building.
(5) Wall signs should be consolidated within three locations. However, outdoor advertising materials for management purposes are excluded.
(6) The number of advertising towers and billboards to be installed on the premises shall be within two, the height from the ground surface shall be 5 m or less, and the display area per unit shall be within 3 m2. However, outdoor advertising materials for management purposes are excluded.
(7) The number of sleeve signs to be installed on the building shall be no more than two, the horizontal distance from the building to the tip of the advertising material shall be within 1.0m, and the display area per unit shall be within 15m2. However, outdoor advertising materials for management purposes are excluded.
(8) Do not install rooftop signs.
(9) Avoid excessive lighting of outdoor advertising materials and do not install anything that flashes light sources.

Minimum of greening rate of buildings 22.5/100

◆Because restrictions on forms or designs such as buildings in the Shin-Sugita Station south district are stipulated in the City Planning Ordinance, procedures for certification of form design are required in addition to the notification.
◆Because "minimum of tree planting rate" of Shin-Sugita Station south district is stipulated in the City Planning Ordinance, procedures such as certificates on conformity with the greening rate may be required before reporting.

For inquiries to this page

Urban Development Bureau Community Development Department Community Development Division

Phone: 045-671-2667

Phone: 045-671-2667

Fax: 045-663-8641

Email address: tb-chiikimachika@city.yokohama.jp

Return to the previous page

Page ID: 721-632-078

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews