Types of specific facilities under the Noise Control Law and Vibration Control Law

Last update date April 10, 2024

Type of specific facilities (noise)

Specific facilities stipulated by the Noise Control Law (Article 2 of the Noise Control Law, Article 1 of the Noise Control Law Enforcement Order, Appendix 1)

1

Metalworking machines

(B) Rolling machines (limited to those with a total of the rated output of the prime mover of 22.5 kW or more)
(B) Piping Machinery
Havending machines (limited to roll type with a rated output of the prime mover of 3.75 kW or more)
(D) Hydraulic press (excluding correction press)
(E) Mechanical press (limited to those with a nominal pressurization capacity of 294 kN or more)
F Shearing machine (limited to motors with a rated output of 3.75 kW or more)
To forging machine
Chiwor formatting machine
Riblast (other than tumblers, excluding sealed type)
Nutambuller
Cutting machines (limited to those that use skewers)

2

Air compressors (except those specified by the Minister of the Environment as not generating noise exceeding a certain limit, limited to those with a rated output of 7.5 kW or more) and blowers (rated output of the prime mover is 7.5 kW or more.) Limited to those above.)

3

Crushers, attributors, sieves and classifiers for debris or minerals (limited to motors with a rated output of 7.5 kW or more)

4

Looms (limited to those that use motors)

5

Construction Materials Manufacturing Machines

Ikon Crete plant (except for air concrete plants, kneading capacity of the kneading machine is limited to 0.45 cubic meters or more.)
Roasfat plant (mixing weight of the kneading machine is 200kg or more)

6

Grain mills (roll type, limited to prime mover with a rated output of 7.5 kW or more)

7

Wood processing machines

Idrum barker
Rotipper (limited to motors with a rated output of 2.25 kW or more)
(C) C crusher
(D) Band sawing machine (for sawmills, the rated output of the prime mover is 15 kW or more, and for woodwork, the rated output of the prime mover is 2.25 kW or more.)
(E) Round sawing machine (for sawmills, the rated output of the prime mover is 15 kW or more, and for woodwork, the rated output of the prime mover is 2.25 kW or more.)
F Plane board (limited to motors with a rated output of 2.25 kW or more.)

8

Paper machine

9

Printing machines (limited to those that use motors)

10

Injection molding machines for synthetic resins

11

Mold molding machine (limited to jolt type)

Type of specific facilities (vibration)

Specific facilities stipulated by the Vibration Regulation Law (Article 2 of the Vibration Regulation Law, Article 1 of the Vibration Regulation Law Enforcement Order, Appendix 1)

1

Metalworking machines

B. Hydraulic presses (excluding correction presses)
(B) Mechanical Press
(C) Shearing machine (limited to motors with a rated output of 1 kW or more)
D. Forging machine
Heuerforming machine (limited to motors with a rated output of 37.5 kW or more)

2

Compressors (except those specified by the Minister of the Environment as not generating vibration that exceeds a certain limit, limited to those with a rated output of 7.5 kW or more of the prime mover)

3

Crushers, attributors, sieves and classifiers for debris or minerals (limited to motors with a rated output of 7.5 kW or more)

4

Looms (limited to those that use motors)

5

Concrete block machines (limited to those with a total of the rated output of the prime mover of 2.95 kW or more) and concrete pipe making machines and concrete pillar making machines (limited to those with a total rated output of the prime mover of 10 kW or more.)

6

Wood processing machines

Idrum barker
Rochipper (limited to motors with a rated output of 2.2 kW or more)

7

Printing machines (limited to motors with a rated output of 2.2 kW or more)

8

Rolling machine for kneading rubber or kneading synthetic resin (limited to those with a rated output of the prime mover of 30 kW or more other than calender roll machines)

9

Injection molding machines for synthetic resins

10

Mold molding machine (limited to jolt type)


For inquiries to this page

Atmosphere and Sound Environment Division Environmental Conservation Department, Green Environment Bureau

Phone: 045-671-2485

Phone: 045-671-2485

Fax: 045-550-3923

Email address: mk-souon@city.yokohama.lg.jp

Return to the previous page

Page ID: 548-578-708

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews