Menu

Close

Here's the text.

Partial revision of the Noise Control Law Enforcement Order and the Vibration Control Law Enforcement Order

Last update date April 10, 2024

Outline of Revision

A Cabinet Order amending a part of the Noise Control Law Enforcement Order and the Vibration Control Law came into force on December 1, 2022.

Noise

Regarding air compressors specified in Appendix 1 of the Enforcement Ordinance of the Noise Control Law, those designated by the Minister of the Environment as not generating noise exceeding a certain limit will be excluded from regulation.

Paragraph 1 of the Noise Control Law Enforcement Order Noise Control Law
Prior to revision After the revision
Air compressors and blowers (limited to motors with a rated output of 7.5 kW or more) Air compressors (except those specified by the Minister of the Environment as not generating noise exceeding a certain limit, limited to those with a rated output of 7.5 kW or more) and blowers (rated output of the prime mover is 7.5 kW or more.) Limited to those above.)

※No designation will be made by the Minister of the Environment in this amendment.


Vibration

Regarding the requirements for compressors specified in Appendix 1 of the Ordinance for Enforcement of the Vibration Regulation Law, those specified by the Minister of the Environment as not generating vibration exceeding a certain limit will be excluded from regulation.

Paragraph 1_2 of the Ordinance for Enforcement of the Vibration Control Law
Prior to revision After the revision
Compressors (limited to motors with a rated output of 7.5 kW or more) Compressors (except those specified by the Minister of the Environment as not generating vibration that exceeds a certain limit, limited to those with a rated output of 7.5 kW or more of the prime mover)

The "Notification of Determining Compressors Designated by the Minister of the Environment as not to generate vibration exceeding a certain limit" and the "Regulations on Designation of Low Vibration Compressors" came into effect on December 1, 2022, which stipulated specifications for compressors not subject to regulation.

Compressors designated by the Minister of the Environment as not to generate vibrations that exceed a certain limit.
Low vibration compressor The compression method of the equipment is screw type, assuming that the vibration at a point 5 m away from the device does not exceed 60 dB in normal operation at factories and business sites.
Model Manufacturers whose application has been individually designated by the Minister of the Environment

Designation of low-vibration compressor

Low vibration compressors specified by the Ministry of the Environment are not subject to the Vibration Regulation Law.
Please refer to the Ministry of the Environment website for the status of model designation.
[Ministry of the Environment] Designation of low-vibration compressor type (external site)

Report on low-vibration compressors that have been reported as specific facilities

In accordance with the designation of the type of low-vibration compressor by the Ministry of the Environment, Yokohama City reports on specific facilities that are no longer applicable to factories or business establishments that have reported compressors based on the Vibration Control Law. I'm asking. For more information, please refer to the following page.
[Vibration] Report on low-vibration compressors that have been reported as specific facilities (outside site)

Reference link

For inquiries to this page

Atmosphere and Sound Environment Division Environmental Conservation Department, Green Environment Bureau

Phone: 045-671-2485

Phone: 045-671-2485

Fax: 045-550-3923

Email address: mk-souon@city.yokohama.lg.jp

Return to the previous page

Page ID: 620-679-202

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews