Procedures for soot and smoke generating facilities

Last Updated April 10, 2024

This section provides an overview of notification procedures and regulatory standards based on the Air Pollution Control Law for soot and smoke generation facilities.

1 Outline of the notification procedure

When setting up or changing soot and smoke generating facilities, or when the corporate representatives listed in the notification of soot and smoke generating facilities are changed, a notification procedure based on the Air Pollution Control Law is required. (Guide for notification pertaining to soot and smoke generating facilities (PDF: 713KB)
In addition, when submitting a notification pertaining to a soot and smoke generating facility based on the Air Pollution Control Law, if the facility falls under the designated facility of the Ordinance on conservation, etc. of the Yokohama City Living Environment (hereinafter referred to as the “Ordinance”), You will also need to apply for permission, so please check at the section in charge.

Table
Laws and regulationsFacilitiesProceduresContents
Air Pollution Control LawSoot and smoke generation facilitiesNotificationInstallation, change, name change, succession, abolition, etc.
Ordinance on conservation, etc. of Yokohama City Living EnvironmentDesignated facilities (PDF: 370KB)Permission application or notificationInstallation, change, name change, succession, abolition, etc.

2 Regarding regulatory standards, etc.

Regarding regulatory standards for the prevention of air pollution, in addition to emission standards for soot and smoke generation facilities stipulated in the Air Pollution Control Law, it is necessary to comply with the regulatory standards of the Ordinance on conservation, etc. of the Yokohama City Living Environment. There are other guidelines, so please check at the section in charge for details.

3 About notification procedure about soot and smoke generating facilities

For details on reports, etc., be sure to check in advance at the section in charge. For the notification, please fill out the prescribed form with required items and submit the attached documents explaining the details. Also, please unify the size of the registration form documents to A4 and fold large drawings to A4.
In addition, we may not be able to accept documents if there are incomplete documents, so please allow enough time for submission.

(1) Notification of installation of soot and smoke generating facilities

Table
Subsidiary provisionsArticle 6 of the Air Pollution Control Law
StyleInstallation (use, change) registration form [Form No. 1 (Attachment 1, Attachment 2, Attachment 3)] (External site)
Number of copies submitted2 copies of primary and secondary copies
Submission deadlineInstallation work cannot be performed until 60 days have passed since the date the notification was received. However, depending on the results of the examination after receiving the notification, the implementation restriction period may be shortened. (Article 10 of the Air Pollution Control Law)
RemarksIn the case of notification, be sure to consult with the section in charge in advance.

[attached documents]
Depending on the content of the notification, in addition to the materials shown here, there may be cases where it is necessary or unnecessary, so please check at the counter at the time of notification. In addition, multiple contents may be summarized in one drawing, but be careful not to make the contents difficult to understand.

Table
DocumentsRemarks
Overview of the contents of the notificationIn addition to the reasons for notification, etc., please summarize how to use the soot generating facility, an overview of the generation and treatment method of soot, and an overview of the production process (flowsheet, etc.).
Guide mapAttach a map that shows the location of the establishment where the soot and smoke generation facility is installed.
Floor plan of business sitesMark soot and smoke generating facilities, flue, chimney, etc. with a color pen, etc., and enter the facility number, facility name, and chimney number.
Layout of soot and smoke generating facilities
(floor plan, elevation)
Mark the target facility with a color pen, etc., and enter the facility number and facility name.
Structural diagram of soot and smoke generating facilities 
Specifications, catalogs, etc. of soot and smoke generating facilitiesAttach one that can confirm the scale requirements of the soot and smoke generation facility (burner fuel combustion capacity, heat transfer area, rated capacity of transformer, etc.).
Fuel piping diagramSpecify the position of the flow meter.
[Caution] About flow meter
  • Please install the flow meter for each facility.
Flue diagramShow the flue from the soot and smoke generating facility to the chimney.
Please specify the inner diameter of the flue.
Structure diagram of the chimneySpecify the height and inner diameter of the outlet from the ground.
Position map of the measuring portSpecify the position and size of the measurement port of soot and smoke, and also specify the inner diameter of the flue at the location where the measurement port is installed.
[Caution] About measuring mouth
  • The measurement port should be installed for each soot and smoke generation facility.
  • If there are multiple discharge outlets, in principle, all discharge outlets must be provided with measurement outlets.
  • Avoid the bent part of the flue and make sure that the exhaust gas from other facilities does not join.
  • In principle, the size and shape of the measuring port should be a flange with an inner diameter of about 100 mm.
Statement of soot and smokePlease attach a statement such as the amount of soot and exhaust gas for soot and smoke discharged from the soot generating facility.
[Caution] About exhaust gas coefficient
  • Use the following values for the emission factors of city gas 13A.
    (wet) 11.79m3N/m3N, (dry) 9.62m3N/m3N (both residual oxygen concentration 0%)
  • For other fuels, please contact the office.
Guarantee of soot and smoke concentrationAttach the manufacturer's warranty regarding the concentration of soot and smoke emitted from nitrogen oxides. For those that are stipulated to be converted to oxygen concentration, the emission concentration converted to the standard oxygen concentration (for example, 5% for gas-burned boilers) specified for each soot and smoke generation facility should be understood.
Smoke treatment system diagramBe sure to understand the sequence of soot and smoke treatment.
Layout of soot and smoke treatment facilities
(floor plan, elevation)
Please state the name of the main equipment.
Structural diagram of soot and smoke treatment facilities 
Specifications, calculations, catalogs, etc. of soot and smoke treatment facilitiesAttach a copy that shows the performance (processing efficiency, etc.) of the soot and smoke treatment facility.
Destination of documents, etc.Your contact information will be sent to you after the registration form review. Attach the name, postal code, location, and address (department section name, person in charge) of the destination.
OthersPlease attach necessary instructions according to the content of the notification.

(2) Notification of change in soot and smoke generating facilities

Table
Subsidiary provisionsArticle 8 of the Air Pollution Control Law
StyleInstallation (use, change) registration form [Form No. 1 (Attachment 1, Attachment 2, Attachment 3)] (External site)
Number of copies submitted2 copies of primary and secondary copies
Submission deadlineChanges cannot be made until 60 days have passed since the date the notification was received. However, depending on the results of the examination after receiving the notification, the implementation restriction period may be shortened. (Article 10 of the Air Pollution Control Law).
RemarksIn the case of notification, be sure to consult with the section in charge in advance.

[attached documents]
Depending on the content of the notification, in addition to the materials shown here, there may be cases where the same thing as attached documents in “(1) Notification of installation of soot and smoke generating facilities” is required or unnecessary. Please check at the counter. In addition, multiple contents may be summarized in one drawing, but be careful not to make the contents difficult to understand.

Table
DocumentsRemarks
Overview of the contents of the notificationPlease summarize the changes in addition to the reasons for notification.
Guide mapPlease attach a map that shows the location of the establishment pertaining to the notification.
Floor plan of business sitesMark soot and smoke generating facilities, flue, chimneys, etc. to be changed with a color pen, etc., and enter the facility number, facility name, and chimney number.
Layout of soot and smoke generating facilities
(floor plan, elevation)
Mark the facilities to be changed with a color pen, etc., and enter the facility number and facility name.
Drawings showing changesPlease show the drawings before and after the change of the items to be changed. Mark the target facilities and the parts to be changed with a color pen etc.
Explanatory materials for changesMark the parts to be changed with a color pen or the like. If necessary, please attach the materials before and after the change.
Destination of documents, etc.Your contact information will be sent to you after the registration form review. Attach the name, postal code, location, and address (department section name, person in charge) of the destination.
OthersPlease attach necessary instructions according to the content of the notification.

(3) Notification of change in name, etc.

Table
Subsidiary provisionsArticle 11 of the Air Pollution Control Law
StyleName Change registration form (outside site)
Number of copies submitted2 copies of primary and secondary copies
Submission deadlineWithin 30 days from the date of change
Details of notificationChanges related to the following:
  • Name or name and in the case of Address or a corporation, the name of the representative
  • Name and location of a factory or business site

(4) Notification of abolition of soot and smoke generating facilities

Table
Subsidiary provisionsArticle 11 of the Air Pollution Control Law
StyleAbolished use of soot and smoke generating facilities registration form [Form No. 5] (outside site)
Number of copies submitted2 copies of primary and secondary copies
Submission deadlineWithin 30 days from the date of abolition
Details of notificationAbolition of soot and smoke generating facilities
RemarksMake sure that all soot and smoke generating facilities installed at the establishment are abolished or some soot generating facilities are abolished. If necessary, please attach a document that shows the new situation associated with the abolition of the facility (such as what the facility is to be updated).

(5) Notification of succession of soot and smoke generating facilities

Table
Subsidiary provisionsArticle 12 of the Air Pollution Control Law
StyleSuccession registration form (outside site)
Number of copies submitted2 copies of primary and secondary copies
Submission deadlineWithin 30 days from the date of succession
Details of notificationSuccession of soot and smoke generating facilities
RemarksMake sure that all soot and smoke generating facilities installed at the establishment are succeeded or that some soot generating facilities are succeeded. In the case of succession of some facilities, please attach a document that can identify the facilities that have been succeeded as necessary.

4. Obligation to measure soot concentration, etc.

The installer of the soot generating facility must measure the concentration of soot and smoke emitted from the soot generating facility, record the results, and save them. (Article 16 of the Air Pollution Control Law)

If the soot and smoke generating facility falls under the designated facility stipulated in the Ordinance on conservation, etc. of Yokohama City Living Environment, in addition to the obligation to measure soot and smoke concentration, etc. based on the Air Pollution Control Law, it is also necessary to comply with the measurement obligations. In this case, the ordinance requires that records of measurement results be kept for three years, and facilities with a measurement frequency of at least once every five years must be kept for five years. (Article 27 of the Ordinance on conservation, etc. of Yokohama City Living Environment, Article 33 of the Enforcement Regulations)
Specifically, please confirm "page of the regulations about conservation of Yokohama-shi living environment".

5. Responsibilities of Business Operators

In addition to measures related to the emission of soot and smoke based on the Air Pollution Control Law, businesses shall grasp the status of the emission of soot and smoke into the atmosphere associated with business activities and take necessary measures to control the emission. Must be (Article 17-2 of the Air Pollution Control Act)

6 Notification Address and Inquiries

Please refer to "Information for Inquiry and Notification Desk".
In addition, depending on the content of the notification and consultation, it may take some time to confirm, so please come with plenty of time.

You may need a separate PDF reader to open a PDF file.
If you do not have it, you can download it free of charge from Adobe.
Get Adobe Acrobat Reader DCTo download Adobe Acrobat Reader DC

Inquiries to this page

Atmosphere and Sound Environment Division, Environmental Protection Department, Green Environment Bureau

Telephone: 045-671-3843

Telephone: 045-671-3843

Fax: 045-550-3923

Email address: mk-taikikisei@city.yokohama.lg.jp

Return to the previous page

Page ID: 921-246-504

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews