Menu

Close

Here's the text.

List of specific facilities (2)

Last Updated May 9, 2024

Related to "Dioxins Countermeasures Special Measures Law Enforcement Order Schedule 2 (External Site)"

List of specific facilities
Specific facility numberType of specific facilities
1Bleaching facility with chlorine or chlorine compounds used for the production of sulfate pulp (craft pulp) or sulfate pulp (sulfite pulp).
2Acetylene cleaning facility for use in the production of carbide method
3Among facilities used for the manufacture of potassium sulfate, waste gas cleaning facilities
4Among facilities used for manufacturing alumina fiber, waste gas cleaning facilities
5Waste gas cleaning facilities among facilities that treat gas generated from firing furnaces used for the manufacture of catalysts with carriers (limited to those that use chlorine or chlorine compounds).
6Ethylene dichloride cleaning facility for use in the manufacture of vinyl chloride monomers
7Among the facilities used for the production of caprolactam (limited to those that use nitrosyl chloride), the following facilities
(b) Sulfuric acid concentration facility
(b) Cyclohexane separation facility
(a) Waste gas cleaning facility
8Among facilities used for the manufacture of chlorobenzene or dichlorobenzene, the following:
(b) Washing facilities
(b) Waste gas cleaning facility
94-Among the facilities used for the production of sodium chlorophathalate, the following:
(b) Filtration facilities
(b) Drying facilities
(a) Waste gas cleaning facility
102,3-dichlorro-1,4-Among the facilities used for the manufacture of Naftquinone, the following:
(b) Filtration facilities
(b) Waste gas cleaning facility
118,18-dichlorro-5,15-diethyl-5,15-dihydrodiindro (3,2-b:3',2'-m) Trifenodioxazine (also known as dioxazine violet. In c, it is simply referred to as "dioxazine violet". ) Of the facilities used for manufacturing, the following:
(b) Nitrodial derivative separation facility and reduction derivative separation facility
(b) Nitroide cleaning facility and reduction derivative cleaning facility
(a) Dioxazine violet cleaning facility
(d) Hot air drying facility
12Facilities that treat gas generated from roasting furnaces, melting furnaces, or drying furnaces used for the manufacture of aluminum or its alloys, the following:
(b) Waste gas cleaning facility
(b) Wet-type dust collection facility
13Among the facilities used for collecting zinc (limited to the collection of soot and dust generated from electric furnaces used for steelmaking and collected by dust collectors), the following facilities
(b) Refining facilities
(b) Waste gas cleaning facility
(a) Wet-type dust collection facility
14Recovery of metal from catalysts with carrier (limited to used ones) (by adding soda ash and processing it in a roasting furnace and extracting it with alkaline (limited to those not treated in a roasting furnace) Of the facilities to be used for
(b) Filtration facilities
(b) Refining facilities
(a) Waste gas cleaning facility
15Among the facilities that treat gas generated from waste incinerators listed in Appendix 1, Item 5 (* 1), the following facilities and ash storage facilities generated in the waste incinerator that discharges sewage or wastewater What to do
(b) Waste gas cleaning facility
(b) Wet-type dust collection facility
16Facilities listed in Article 7, Item 12-2 and 13 (outside site) of the Waste Management and Public Cleansing Law Enforcement Ordinance (Government Ordinance No. 300 of 1971) (External Site) Cleaning facility or separation facility for PCB contaminants or PCB waste cleaning facility or separation facility for PCB contaminants or PCB waste)
17Destruction of Freon (refer to specific substances listed in paragraphs 1, 3, and 6 of Appendix 1 of the Law Enforcement Ordinance on the Protection of the Ozone Layer by Regulation of Specific Substances (Government Ordinance No. 308 of 1994)) (Limited to those by methods of destroying using plasma and other methods specified by an Ordinance of the Ministry of the Environment.)
(b) Plasma reaction facility
(b) Waste gas cleaning facility
(a) Wet-type dust collection facility
18Sewerage terminal treatment facility (limited to those that treat sewage including sewage or wastewater pertaining to facilities listed in the first to the preceding item and the next item)
19Water discharged from factories or business establishments that install facilities listed in items 1 to 17 (treatment of sewage or wastewater pertaining to facilities listed in items 1 to 17 or treated sewage or wastewater treatment facilities (excluding those listed in the preceding item) (excluding those listed in the preceding item)

Amended on August 15, 2005

※1
Waste incinerators with a slab area (if two or more waste incinerators are installed in the waste incineration facility, the total of those slave area) of 0.5 m2 or more or an incineration capacity ( If two or more waste incinerators are installed in the waste incineration facility, the total of their incineration capacity) is 50 kg or more per hour

For inquiries to this page

Sewerage River Bureau Sewerage Facilities Department Water Quality Section Factory

Phone: 045-671-2835

Phone: 045-671-2835

Fax: 045-550-4183

Email address: gk-kouhai@city.yokohama.lg.jp

Return to the previous page

Page ID: 357-429-743

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews