Menu

Close

Here's the text.

List of Specific Facilities (2)

Last Updated November 5, 2024

Related to "Dioxins Measures Special Measures Law Enforcement Ordinance Appendix No. 2 (outside site)"

List of specified facilities
Specific facility numberType of specified facilities
1Bleaching facilities with chlorine or chlorine compounds used for the production of sulfuric acid pulp (craft pulp) or sulfuric acid pulp (salfite pulp).
2Acetylene cleaning facility used for the production of carbide acetylene
3Waste gas cleaning facilities among facilities used for the production of potassium sulfate
4Waste gas cleaning facilities among facilities used for the production of alumina fiber
5Waste gas cleaning facilities among facilities that treat gas generated from firing furnaces used for the production of catalysts with carriers (limited to those that use chlorine or chlorine compounds)
6Ethylene dichloride cleaning facility used for the production of vinyl chloride monomers
7Of the facilities to be used for the production of caprolactam (limited to those using nitrosil chloride), the following
(b) Sulfuric acid concentration facility
(b) Cyclohexane separation facility
(c) Waste gas cleaning facility
8Of the facilities used for the production of chlorobenzene or dichlorobenzene, the following:
(b) Washing facilities
(b) Waste gas cleaning facility
94- Among the facilities provided for the production of sodium chlorophthalate, the following:
(b) Filtration facilities
(b) Drying facilities
(c) Waste gas cleaning facility
102,3-dichloro-1,4-Naftquinone facilities provided for the production of the following:
(b) Filtration facilities
(b) Waste gas cleaning facility
118,18-dichloro-5,15-dietyl-5,15-dihydrodiindroid (3,2-b:3',2'-m) triphenodioxazine (also known as dioxazine violet). (C) simply referred to as "dioxazine violet". ) Of the facilities used for manufacturing, the following
(b) Nitrogen derivative separation facility and reduction derivative separation facility
(b) Nitrogen derivative cleaning facility and reduction derivative cleaning facility
(c) Dioxazine violet cleaning facility
(ni) Hot air drying facility
12Facilities that treat gas generated from roasting furnaces, melting furnaces, or drying furnaces used for the production of aluminum or its alloys:
(b) Waste gas cleaning facility
(b) Wet-type dust collection facilities
13Among the facilities to be used for the collection of zinc (soot generated from electric furnaces used for steelmaking and limited to the collection of zinc from those collected by dust collectors), the following:
(b) Refining facilities
(b) Waste gas cleaning facility
(c) Wet-type dust collection facilities
14Collection of metals from catalysts with carriers (limited to used ones) (excluding those by adding soda ash and processing it in a roasting furnace and extracting it with alkaline (limited to those not processed by roasting furnace)) Of the facilities to be used for the following
(b) Filtration facilities
(b) Refining facilities
(c) Waste gas cleaning facility
15Of the facilities that treat gas generated from the waste incinerators listed in Attachment No. 1, Item 5 (* 1), the following and the ash storage facilities generated in the waste incinerator, which discharge sewage or wastewater What you do
(b) Waste gas cleaning facility
(b) Wet-type dust collection facilities
16Facilities listed in Article 7, item 12-2 and item 13 (outside site) of the Enforcement Ordinance on Waste Disposal and Public Cleansing (Government Ordinance No. 300 of 1971) (outside site) (disassembly facilities for waste PCB, etc. or PCB processed goods, cleaning facilities or separation facilities for PCB contaminants or PCB processed goods)
17Destroy of CFCs (refers to specified substances listed in paragraphs 1, 3 and 6 of the Enforcement Ordinance on the Protection of the Ozone Layer by Regulation of Specific Substances (Government Ordinance No. 308 of 1994) Of the facilities to be used for use in plasma and other methods specified by an Ordinance of the Ministry of the Environment.)
(b) Plasma Reaction Facilities
(b) Waste gas cleaning facility
(c) Wet-type dust collection facilities
18Sewerage terminal treatment facilities (limited to those that treat sewage including sewage or wastewater pertaining to the facilities listed in the next item from the first to the preceding item and the facilities listed in the next item.)
19Water discharged from factories or business establishments that install facilities listed in items 1 to 17 (sewage or wastewater pertaining to facilities listed in items 1 to 17 or those that treated the sewage or wastewater) Treatment facilities (excluding those listed in the preceding item) for treatment facilities (excluding those discharged into public water bodies)

Revised on August 15, 2005

※1
Waste incinerators with a burnt area (if two or more waste incinerators are installed in waste incineration facilities, the total of those burnt areas) of 0.5 m2 or more or incineration capacity ( If two or more waste incinerators are installed in waste incineration facilities, the total of their incinerators) is 50 kg or more per hour

Inquiries to this page

Sewer River Bureau Sewerage Facilities Department Water Quality Section Factory Drainage

Telephone: 045-671-2835

Telephone: 045-671-2835

Fax: 045-550-4183

Email address: gk-kouhai@city.yokohama.lg.jp

Return to the previous page

Page ID: 357-429-743

Menu

  • LINE
  • Twitter
  • Facebook
  • Instagram
  • YouTube
  • SmartNews