ItemThe standard valueMethod for measurement
1Cadmium0.01 mg/l or lessJapanese Industrial Standards (we say "standard" as follows.) Method to set of 55 of K0102
2All cyanDo not be detectedMethod to fix for 38.1.2 of standard K0102 and 38.2 or method to set of 38.1.2 of standard K0102 and 38.3
3Lead0.01 mg/l or lessMethod to set of 54 of standard K0102
4Hexavalent chromium0.05 mg/l or lessMethod to fix for 65.2 of standard K0102
5Arsenic0.01 mg/l or lessMethod to fix for 61.2 of standard K0102 or 61.3
6Total mercury0.0005 mg/l or lessMethod to advocate Ministry of the Environment notification No. 59 (about environmental standard to affect water pollution) in appended chart 1 (says "public waters notification" as follows.) in December, 1971
7Alkyl mercuryDo not be detectedMethod to advocate in public waters notification appended chart 2
8PCBDo not be detectedMethod to advocate in public waters notification appended chart 3
9Dichloromethane0.02 mg/l or lessMethod to fix for 5.1, 5.2 of standard K0125 or 5.3.2
10Carbon tetrachloride0.002 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1, 5.4.1 of standard K0125 or 5.5
111,2-dichloroethane0.004 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1 of standard K0125 or 5.3.2
121,1-dichloroethylene0.1 mg/l or lessMethod to fix for 5.1, 5.2 of standard K0125 or 5.3.2
13Cis-1,2-dichloroethylene0.04 mg/l or lessMethod to fix for 5.1, 5.2 of standard K0125 or 5.3.2
141,1,1,-trichloroethane1 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1, 5.4.1 of standard K0125 or 5.5
151,1,2,-trichloroethane0.006 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1, 5.4.1 of standard K0125 or 5.5
16Trichloroethylene0.03 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1, 5.4.1 of standard K0125 or 5.5
17Tetrachloroethylene0.01 mg/l or lessMethod to fix for 5.1, 5.2, 5.3.1, 5.4.1 of standard K0125 or 5.5
181,3-dichloropropene0.002 mg/l or lessMethod to fix for 5.1, 5.2 of standard K0125 or 5.3.1
19chiuramu0.006 mg/l or lessMethod to advocate in public waters notification appended chart 4
20Simazine0.003 mg/l or lessMethod to advocate to the first or the second of public waters notification appended chart 5
21chiobenkarubu0.02 mg/l or lessMethod to advocate to the first or the second of public waters notification appended chart 5
22Benzene0.01 mg/l or lessMethod to fix for 5.1, 5.2 of standard K0125 or 5.3.2
23Selenium0.01 mg/l or lessMethod to fix for 67.2 of standard K0102 or 67.3
24Nitric acid-related nitrogen and
Nitric acid-related nitrogen
10 mg/l or lessMethod to set of 43.1 of standard K0102 when there is to method to set of 43.2.1, 43.2.3 of standard K0102 or 43.2.5, nitric acid-related nitrogen when it is in nitric acid-related nitrogen
25Fluorine0.8 mg/l or lessMethod to fix for 34.1 of standard K0102 or method to advocate in public waters notification appended chart 6
26Boron1 mg/l or lessMethod to fix for 47.1 of standard K0102 or 47.3 or method to advocate in public waters notification appended chart 7

※ By revision of February, 1999 (Heisei 11), three items of No. 24-26 were added.

[remarks]
1 standard value assumes the annual mean.
But, about the standard value to affect all cyan, we assume high.
When we measure 2 by method to advocate in column of method for measurement that "do not be detected", we call that the result is less than fixed-quantity limit of the method concerned.
About 3 sea areas, the standard value of "fluorine" and "boron" does not apply.
We do conversion factor 0.3045 with the sum of thing which took advantage to density of nitric acid-related ion measured by 43.1 of standard K0102 that the density of 4 nitric acid-related nitrogen and nitric acid-related nitrogen multiplied conversion factor 0.2259 by density of nitric acid-related ion measured by 43.2.1, 43.2.3 of standard K0102 or 43.2.5.
We intend for all 5 public waters and groundwater.
Achievement of 6 period : We are accomplished after the setting promptly and shall try to be maintained.
Guideline level
ItemGuideline level
1Chloroform0.06 mg/l or less
2Trans-1,2-dichloroethylene0.04 mg/l or less
31,2-dichloropropene0.06 mg/l or less
4p-dichlorobenzene0.3 mg/l or less
5isokisachion0.008 mg/l or less
6Die horse mackerel non0.005 mg/l or less
7Fenitrothion (MEP)0.003 mg/l or less
8Isoprofessional thioorchid0.04 mg/l or less
98-quinolinol copper (organic copper)0.04 mg/l or less
10Chlorothalonil (TPN)0.05 mg/l or less
11Propyzamide0.008 mg/l or less
12EPN0.006 mg/l or less
13Dichlorvos (DDVP)0.008 mg/l or less
14Feh knob Caleb (BPMC)0.03 mg/l or less
15ipurobenhosu (IBP)0.008 mg/l or less
16Chlor nitro fen (CNP)
17Toluene0.6 mg/l or less
18Xylene0.4 mg/l or less
19Phthalate diethyl hexyl0.06 mg/l or less
20Nickel
21Molybdenum0.07 mg/l or less
22Antimony
(1) River
TypeAdaptability of the use purposeThe standard value
  Hydrogen ion
Density index
(pH)
Biologic
Oxygen demand
(BOD)
Float mass
(SS)
Oxygen content of water
(DO)
Escherichia coli
The number of the groups
DThe water for industrial use second grade
Agriculture water
And we advocate in column of E
More than 6.0
8.5 or less
8 mg/l or less100 mg/l or less2 mg/l or more
EThe water for industrial use third grade
Environmental conservation
More than 6.0
8.5 or less
10 mg/l or lessFloating such as garbage
Do not be recognized
2 mg/l or more
[remarks]
1 standard value assumes the days mean (wetlands, sea area follow this, too.) .
In the river in two, other rivers are E types with D type section than Toriyama River junction of the Tsurumi River of upper reaches and whole Sakai River.
Achievement of 3 period : We shall plan the achievement maintenance as soon as possible while being combined with promotion of measure.
(2) Sea area
TypeAdaptability of the use purposeThe standard value
  Hydrogen ion
Density index
(pH)
Chemical
Oxygen demand
(COD)
Oxygen content of water
(DO)
Escherichia coli
The number of the groups
n-hexane
Extraction material
(oil contents)
BThe fisheries second grade
Water for industrial use
And we advocate in column of C
 More than 7.8
 8.3 or less
 3 mg/l or less 5 mg/l or more We are detected
Few thing
CEnvironmental conservation More than 7.0
 8.3 or less
 8 mg/l or less 2 mg/l or more  
Type
TypeAdaptability of the use purposeThe standard value
  All nitrogenTotal phosphorus
IIIWe advocate in column of two kinds of fisheries and IV
(except three kinds of fisheries)
0.6 mg/l or less0.05 mg/l or less
IVThree kinds of fisheries, water for industrial use,
Living thing biotope maintenance
1 mg/l or less0.09 mg/l or less
[remarks]
1 standard value assumes the annual mean of the upper air.
We shall perform designation of 2 topology of water regions about sea area that might produce remarkable increase of marine phytoplankton.

(note) two kinds of 1 fisheries : Except some bottoms raw seafood, it is said fisheries living thing mainly on fish takaku.
Three kinds of fisheries : Specific fisheries living thing resisting contamination is fished mainly.
2 living thing biotope maintenance : Limit that benthos can inhabit through the year.

Of topology of water regions of environmental standards on water pollution to affect all nitrogen, total phosphorus which public waters corresponds to appoint (extract)

Area of the sea
The area of the sea namePertinence
Type
The achievement periodProvisional aim
(1999)
Tokyo Bay (ro)IVWhile achieving provisional aim progressively,
We try for the prompt achievement of environmental standard as possible.
All 1.4 mg/l of nitrogen
0.095 mg/l of total phosphorus
Tokyo Bay (ni)IIIWhile achieving provisional aim progressively,
We try for the prompt achievement of environmental standard as possible.
All 0.97 mg/l of nitrogen
0.067 mg/l of total phosphorus
(note 1) About applicable type, we cope with type of environmental standard to modify all nitrogen of sea area shown in the next figure and total phosphorus.
(note 2) This provisional aim is applied to result of a measurement until 1999 (Heisei 11).

Area of the sea division of environmental standard to affect all nitrogen, total phosphorus

Figure of area of the sea division of environmental standard to affect all nitrogen, total phosphorus

Inquiry to this page

Environmental Planning Bureau environment Maintenance Division Environment Administration Division

Telephone: 045-671-3507

Telephone: 045-671-3507

Fax: 045-641-3580

E-Mail address [email protected]

Return to the previous page

Page ID: 147-027-939

We come back to the top